ALL TESTS CONDUCTED

ON DURALIGHT

®

The properties of Duralight

®

, having a profile of high quality and durability at every

level, have been rigorously tested, applying international standards.

Verified by

LEED (Leadership in Energy and Environmental

Design) is a voluntary certification of the

environmental and economic sustainability of

buildings based on measurable requisites, from

the consumption of environmental resources to

the consumption of energy, and the quality of the

internal environment.

Duralight products, tiles and coverings, along

with all products in the Teuco range, have

undergone LEED mapping.

Based on this process, when used for the

construction of buildings, they can contribute

towards earning certain LEED credits.

30

The test results provided herein

refer to white Duralight

®

.

Physical and mechanical properties of Teuco Duralight

®

PROPERTY*

Determination of the resistance

to chemical agents, stains

and domestic detergents

Determination of the Charpy resilience

Determination of the bending modulus

Resistance to bending

Determination of the tensile modulus

Determination of the bending breakage sigma

Determination of the Rockwell hardness

Fire resistance tests

Ignitability of products

at the Giordano Institute

Smoke classification

at the Giordano Institute

Fire resistance classification

at the Giordano Institute

Fire resistance classification

at the Giordano Institute**

Classification in slip-resistance tests

TYPICAL

RESULTS

Consistent with

all reagents

4.5 KJ/m

2

8.1 Gpa

76.91 Mpa

6.2 Gpa

50.27 Mpa

93.2

Fire classification

class attributed: B

Smoke classification

class attributed: S1

Smoke opacity

classification class

attributed: F0

Drops/particles

ignited absent

Classification: d0

Euroclass:

FIRE

RESISTANCE

CLASSIFICATION is:

B; -s; d0

CLASS (A + B)

TEST

METHOD

RANGE OF

ACCEPTABILITY

UNI EN 14527

UNI EN ISO 179-1

Ref. 3-8 KJ/m

2

UNI EN ISO 178

Ref. 6-10 Gpa

UNI EN ISO 178

Ref. 70-80 Mpa

UNI EN ISO 527-1

Ref. 6-10 Gpa

UNI EN ISO 527-1

Ref. 50-60 Mpa

UNI EN ISO2039-2

Ref. 75-95 HRM

UNI EN ISO 11925-

2:2005 Part 2

UNI EN 13238:2002

Range of resistance

to fire:

Class A2, B, C, D

Range of smoke:

Classification

S1-S2-S3

NF F16-101 (1998)

NF X10-702-2 (1994)

NF X70-100 (2006)

Range of opacity

of smoke F0-F2

UNI EN 13501:2007

UNI EN 13823: 2005

UNI EN 13238: 2002

Range d0-d2

NF F16-101 (1998)

NF X10-702-2 (1994)

NF X70-100 (2006)

UNI EN 13501:2007

UNI EN 13823: 2005

UNI EN 13238: 2002

DIN 51097

UNI EN 13451-1

Range:

Class A - B - C

31