SPECIFICHE TECNICHE
SPECIFICHE TECNICHE
STANDARD INVERTER (R32)
ALTA PREVALENZA
- UM36F / UM42F / UM48F / UM60F
LG partecipa al programma ECP di EUROVENT.
Per verificare la validità della certificazione:
www.eurovent-certification.com
UUD1.U30
5.8 / 14.6 / 15.8
6.7 / 16.8 / 18.1
1.00 / 4.95 / 5.54
0.90 / 4.60 / 5.29
21.6
20.4
2.95 / 3.65
5.60 / 4.00
14.6
9.5
- / -
1,564 / 3,325
4.7
54 / 54
71
Ø 9.52 (3/8)
Ø 15.88 (5/8)
-20 ~ 52
-25 ~ 18
UM60F.N30
1, 220-240, 50
342 / 287 / 242
50 / 45 / 40
1,250 x 360 x 700
43.5
42 / 40 / 39
66
Ø 25.4 / 19.4
Ø 32.0 / 26.0
STANDARD INVERTER (R32)
ALTA PREVALENZA
- UM 36F / UM42F / UM48F / UM60F
LG partecipa al programma ECP di EUROVENT.
Per verificare la validità della certificazione:
www.eurovent-certification.com
UUD3.U30
5.8 / 14.6 / 15.8
6.7 / 16.8 / 18.1
1.00 / 4.95 / 5.54
0.90 / 4.60 / 5.29
7.7
7.2
2.95 / 3.65
5.6 / 4.0
14.6
9.5
- / -
1,564 / 3,325
4.7
54 / 54
71
Ø 9.52 (3/8)
Ø 15.88 (5/8)
-20 ~ 52
-25 ~ 18
UM60F.N30
1, 220-240, 50
342 / 287 / 242
50 / 45 / 40
1,250 x 360 x 700
43.5
42 / 40 / 39
66
Ø 25.4 / 19.4
Ø 32.0 / 26.0
* Comando opzionale da ordinare separatamente
* Comando opzionale da ordinare separatamente
COMBINAZIONE
36
42
Capacità
Potenza assorbita (Set)
Corrente assorbita
EER / COP
SEER / SCOP
Pdesign
Classe di efficienza
energetica (Scala da A+++ a D)
Consumo energetico annuale
Capacità di deumidificazione
Pressione sonora unità esterna
Potenza sonora unità esterna
Diametro tubazioni
di collegamento
Limiti operativi
Alimentazione elettrica
Potenza assorbita (UI)
Capacità di ventilazione
Dimensioni
Peso
Pressione sonora
Potenza sonora
Diametro tubazioni
di collegamento
Alimentazione elettrica
Interruttore magnetotermico
Cavo di alimentazione
Dimensioni
Peso
Compressore
Refrigerante
Capacità di ventilazione
Lunghezza totale tubazioni
Dislivello
Raffrescamento
Riscaldamento
Raffrescamento
Riscaldamento
Raffrescamento
Riscaldamento
Raffrescamento @ 35°C
Riscaldamento @ -10°C
Min / Nom / Max
Min / Nom / Max
Min / Nom / Max
Min / Nom / Max
Nom
Nom
Nom
Nom
Min ~ Max
Min ~ Max
Max / Med / Min
Max / Med / Min
L xA xP
Max / Med / Min
Max.
esterno / interno
esterno / interno
Min
L xA xP
kW
3.8 / 9.5 / 12.5
kW
4.3 / 10.8 / 13.4
kW
0.50 / 2.50 / 3.80
kW
0.60 / 2.77 / 3.77
A
11.1
A
12.6
3.80 / 3.90
5.80 / 3.90
kW
9.5
kW
9.5
-
A+ / A
kWh
573 / 3,410
l/h
2.9
dB(A)
50 / 50
dB(A)
66
Capacità
Potenza assorbita (Set)
Corrente assorbita
EER / COP
SEER / SCOP
Pdesign
Classe di efficienza
energetica (Scala da A+++ a D)
Consumo energetico annuale
Capacità di deumidificazione
Pressione sonora unità esterna
Potenza sonora unità esterna
Diametro tubazioni
di collegamento
Limiti operativi
Alimentazione elettrica
Potenza assorbita (UI)
Capacità di ventilazione
Dimensioni
Peso
Pressione sonora
Potenza sonora
Diametro tubazioni
di collegamento
Alimentazione elettrica
Interruttore magnetotermico
Cavo di alimentazione
Dimensioni
Peso
Compressore
Refrigerante
Capacità di ventilazione
Lunghezza totale tubazioni
Dislivello
Raffrescamento
Riscaldamento
Raffrescamento
Riscaldamento
Raffrescamento
Riscaldamento
Raffrescamento @ 35°C
Riscaldamento @ -10°C
Min / Nom / Max
Min / Nom / Max
Min / Nom / Max
Min / Nom / Max
Nom
Nom
Nom
Nom
Min ~ Max
Min ~ Max
Max / Med / Min
Max / Med / Min
L x Ax P
Max / Med / Min
Max.
esterno / interno
esterno / interno
Min
L x Ax P
kW
3.8 / 9.5 / 12.5
kW
4.3 / 10.8 / 13.4
kW
0.50 / 2.50 / 3.80
kW
0.60 / 2.77 / 3.77
A
4.0
A
4.5
3.80 / 3.90
5.8 / 3.9
kW
9.5
kW
9.5
-
A+ / A
kWh
573 / 3,410
l/h
2.9
dB(A)
50 / 50
dB(A)
66
4.8 / 12.0 / 14.0
9.5
Raffrescamento
Riscaldamento
Raffrescamento
Riscaldamento
Raffrescamento
Riscaldamento
Raffrescamento
Liquido
Gas
Raffrescamento
Riscaldamento
Raffrescamento
Raffrescamento
/
/
/
Raffrescamento
Riscaldamento
Raffrescamento
Riscaldamento
Raffrescamento
Riscaldamento
Raffrescamento
Liquido
Gas
Raffrescamento
Riscaldamento
Raffrescamento
Raffrescamento
/
/
/
A+ / A
5.4 / 13.4 / 15.7
- /-
4.8 / 12.0 / 14.0
9.5
5.4 / 13.4 / 15.7
5.4 / 13.5 / 15.8
6.2 / 15.5 / 17.5
5.4 / 13.5 / 15.8
6.2 / 15.5 / 17.5
0.70 / 3.48 / 4.52
0.80 / 3.74 / 4.86
0.90 / 4.32 / 5.62
0.70 / 3.48 / 4.52
0.90 / 4.32 / 5.62
0.90 / 4.31 / 5.26
0.80 / 3.74 / 4.86
0.90 / 4.31 / 5.26
15.3
19.0
5.5
6.8
16.4
18.4
5.9
6.5
3.45 / 3.61
3.10 / 3.60
3.45 / 3.61
3.10 / 3.60
5.60 / 3.90
5.80 / 4.00
5.6 / 3.9
5.8 / 4.0
12.0
13.4
12
13.4
9.5
A+ / A
9.5
- /-
750 / 3,410
1,386 / 3,325
750 / 3,410
1,386 / 3,325
4.4
4.8
4.4
4.8
51 / 52
52 / 53
51 / 52
52 / 53
69
mm (inch)
mm (inch)
°C
°C
Ø, V, Hz
W
m
3
/min
mm
Ø 9.52 (3/8)
Ø 15.88 (5/8)
-20 ~ 52
-25 ~ 18
1, 220-240, 50
183 / 134 / 101
32 / 28 / 24
1,250 x 270 x 700
mm (inch)
mm (inch)
°C
°C
Ø, V, Hz
W
m
3
/min
mm
Ø 9.52 (3/8)
Ø 15.88 (5/8)
-20 ~ 52
-25 ~ 18
1, 220-240, 50
183 / 134 / 101
32 / 28 / 24
1,250 x 270 x 700
Ø 9.52 (3/8)
69
69
Ø 9.52 (3/8)
69
Ø 9.52 (3/8)
Ø 9.52 (3/8)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
Ø 15.88 (5/8)
-20 ~ 52
-25 ~ 18
-20 ~ 52
-20 ~ 52
-20 ~ 52
-25 ~ 18
-25 ~ 18
-25 ~ 18
UNITÀ INTERNA
UM36F.N20
UM42F.N20
1, 220-240, 50
266 / 200 / 145
UM48F.N30
1, 220-240, 50
UNITÀ INTERNA
UM36F.N20
UM42F.N20
1, 220-240, 50
UM48F.N30
1, 220-240, 50
242 / 159 / 124
266 / 200 / 145
242 / 159 / 124
38 / 33 / 28
40 / 34 / 28
38 / 33 / 28
40 / 34 / 28
1,250 x 270 x 700
1,250 x 360 x 700
1,250 x 270 x 700
1,250 x 360 x 700
kg
38.5
dB(A)
36 / 34 / 33
dB(A)
60
kg
38.5
dB(A)
36 / 34 / 33
dB(A)
60
38.5
38 / 36 / 34
43.5
39 / 38 / 36
38.5
43.5
38 / 36 / 34
39 / 38 / 36
62
65
62
65
Scarico condensa (per gravità)
Scarico condensa (con pompa)
Tipo
Tipo
mm
mm
Ø, V, Hz
Ø 25.4 / 19.4
Ø 32.0 / 26.0
Scarico condensa (per gravità)
Scarico condensa (con pompa)
Tipo
Tipo
mm
mm
Ø, V, Hz
Ø 25.4 / 19.4
Ø 32.0 / 26.0
Ø 25.4 / 19.4
Ø 25.4 / 19.4
Ø 25.4 / 19.4
Ø 25.4 / 19.4
UNITÀ ESTERNA
UUD1.U30
Ø 32.0 / 26.0
1, 220-240, 50
3, 380-415, 50
Ø 32.0 / 26.0
UNITÀ ESTERNA
UUD3.U30
Ø 32.0 / 26.0
Ø 32.0 / 26.0
A
40
No x mm
3
3C x 6.0
mm
950 x 1,380 x 330
kg
85
-
Inverter Scroll
-
R32
-
675
kg
3.0
-
2.025
g/m
40
Nominale
m3/minxNo.
55 x 2
Min / Max
m
5 / 85
A
20
No x mm
3
5C x 2.5
mm
950 x 1,380 x 330
kg
85
-
Inverter Scroll
-
R32
-
675
kg
3.0
-
2.025
g/m
40
Nominale
m3/minxNo.
55 x 2
Min / Max
m
5 / 85
GWP (Global Warming Potential)
Precarica
t-CO
2
eq
Incremento (dopo 7,5 m)
UI - UE
GWP (Global Warming Potential)
Precarica
t-CO
2
eq
Incremento (dopo 7,5 m)
UI - UE
Max
m
30
Max
m
30
48
60
COMBINAZIONE
36
42
48
50
51
Per la nostra politica di continuo miglioramento dei prodotti, le caratteristiche e i dati sopra riportati sono soggetti a modifiche senza obbligo di
preavviso. Le immagini dei prodotti e degli accessori sono puramente
indicative; per esigenze grafiche i colori dei prodotti potrebbero differire dalla realtà. Questi prodotti contengono gas fluorurati ad effetto serra.
Vedi le condizioni di riferimento a pag. 117
Per la nostra politica di continuo miglioramento dei prodotti, le caratteristiche e i dati sopra riportati sono soggetti a modifiche senza obbligo di
preavviso. Le immagini dei prodotti e degli accessori sono puramente
indicative; per esigenze grafiche i colori dei prodotti potrebbero differire dalla realtà. Questi prodotti contengono gas fluorurati ad effetto serra.
Vedi le condizioni di riferimento a pag. 117
60
C
O
M
M
E
R
C
I
A
L
E